Categories
Loading categories…

Edwards Signaling Transformer, Power, 283:70, 130c, 112.2w, Cm

SKU: 2490027 Edwards Signaling

Special Order: typically 2–6 weeks

Ships directly from the manufacturer. This is an estimated lead time, not a guaranteed delivery date.

Availability can change and lead times may be longer. If your project has a deadline, check with us before ordering.

A member of our team will check with the manufacturer and personally reply by email.

Image of ED-2490027
Product images for Edwards Signaling Transformer, Power, 283:70, 130c, 112.2w, Cm. 1 image(s) available. Click on image to view full size.

Key Features

  • Delivers dependable low-voltage power to fire alarm and security systems, minimizing downtime and false alarms.
  • Compact open-frame design simplifies installation into existing fire alarm panels and control cabinets.
  • Stable 120V AC to 26.4V AC conversion with 112.2VA capacity ensures consistent power for monitoring and detection devices.
  • Rated to 130°C for high-temperature reliability in demanding environments and continuous operation.
  • Industry-grade performance supports surveillance, access control, and other life-safety equipment for scalable deployments.

Quick Specifications

Product Model
2490027
Brand Name
Edwards Signaling
Product Name
Transformer
Product Type
Open Frame
View Full Technical Specifications

Explore the details

Product information

2490027

Overview

Ensure uninterrupted operation of your fire alarm and security infrastructure with the Edwards Signaling Transformer, model 2490027. This open-frame transformer is engineered to provide reliable low-voltage power for fire alarm panels, monitoring modules, surveillance interfaces, and other critical safety equipment. With a 120V AC to 26.4V AC conversion and a robust 112.2VA (4.25A) output, it delivers the consistent voltage and current needed to prevent nuisance trips and maintain system integrity.

Built for professional installations, the Edwards Signaling transformer features a compact footprint that eases retrofit into control cabinets and panel layouts. The 130°C temperature rating and trusted Carrier manufacturing mean long-term durability in commercial and industrial environments. Integrators and facility managers will appreciate the predictable performance that keeps detection, notification, and access control systems online.

Ideal for fire alarm panels, security and surveillance systems, and central monitoring applications, the 2490027 transformer helps protect people and property by powering the devices that matter most. Add this reliable power solution to your next installation or replacement project—contact your distributor to order or specify it on your next system design.

Features

  • Delivers dependable low-voltage power to fire alarm and security systems, minimizing downtime and false alarms.
  • Compact open-frame design simplifies installation into existing fire alarm panels and control cabinets.
  • Stable 120V AC to 26.4V AC conversion with 112.2VA capacity ensures consistent power for monitoring and detection devices.
  • Rated to 130°C for high-temperature reliability in demanding environments and continuous operation.
  • Industry-grade performance supports surveillance, access control, and other life-safety equipment for scalable deployments.
10 of 10 specifications
Technical specifications for Edwards Signaling Transformer, Power, 283:70, 130c, 112.2w, Cm
General Information
Brand Name Edwards Signaling
Manufacturer Carrier
Product Name Transformer
Product Type Open Frame
Product Model 2490027
Manufacturer Part Number 2490027
Power Description
Power Rating 112.2VA
Input Voltage 120-26.4V AC
Maximum Line Current 4.25A
Miscellaneous
Country of Origin CA

No matching specifications

Try a different term, such as a connector type or resolution.

Plan your purchase

Is this right for your project?

Confirm the model, required accessories and delivery needs before ordering.

SKU:
2490027
Manufacturer part:
2490027
How do I confirm compatibility?

Check the specifications and manufacturer documents for your existing system. Send us your model numbers and project requirements if you need help selecting equipment or accessories.

Ask a product specialist
When will this item ship?

Availability is shown above. Special-order items and project quantities may need additional lead time. Contact us to confirm a delivery date before scheduling installation.

Shipping, freight and delivery details
What should I know about returns?

Returns require an approved RMA. Consult the linked return policy for deadlines and eligibility. For standard non-defective returns, eligible factory-sealed items carry a 15% restocking fee and customer-paid return shipping; open-box and used items are refused. Defective and DOA claims follow the policy's separate terms. Special orders and other exclusions are final sale.

Read return eligibility and exclusions

Edwards Signaling Transformer, Power, 283:70, 130c, 112.2w, Cm

2490027

Price & options