Potter PAD100-OROI One Relay One Input Module

Potter One Relay One Input Module
Product images for Potter PAD100-OROI One Relay One Input Module. 1 image(s) available. Click on image to view full size.

Key Features

  • Simplifies fire-alarm integration by converting one dry contact into a monitored Class B input and a Form C relay for immediate control actions
  • Reduces installation time with electrical-box mounting, accessible wiring terminals and support for 22–12 AWG conductors
  • Reliable SLC communication using a single loop address (SLC Class A/X/B) for seamless connection to Potter IPA series control panels
  • Visible status LED and DIP-switch addressing for fast troubleshooting and on-site configuration
  • Robust, code-ready design with US manufacture and a 5-year limited warranty for long-term system reliability

Quick Specifications

Product Model
PAD100-OROI
Sector
Fire
Brand Name
Potter Electric Signal, LLC
Product Name
One Relay One Input Module
View Full Technical Specifications

Frequently Bought Together

This Item
Potter PAD100-OROI One Relay One Input Module

Potter PAD100-OROI One Relay One Input Module

$122.53

Frequently Bought Together (2 items)

3 items selected

Total: $313.83

Explore the details

Product information

3992702

Overview

Ensure reliable monitoring and control of a single field device with the Potter Electric Signal PAD100-OROI One Relay One Input Module. Designed for fire alarm and security applications, this relay/input module converts one dry contact (sprinkler waterflow, tamper, or conventional pull station) into a supervised Class B input while providing a Form C relay contact for local control or annunciation. The PAD100-OROI uses one SLC loop address (supports SLC Class A, X and B) and mounts neatly in a standard 4" square or double-gang box, keeping installation tidy and reducing labor. Installers benefit from accessible wiring terminals that accept 22–12 AWG, a red status LED for quick state verification, and DIP-switch addressing for simple on-site setup. Compatible with Potter IPA series control panels, this module streamlines fire alarm panel integration and enhances security and surveillance system monitoring. Backed by a 5-year limited warranty and US manufacturing, the PAD100-OROI is ideal for contractors and system integrators seeking dependable relay interfaces. Add it to your next fire or security installation to simplify monitoring and control.

Features

  • Simplifies fire-alarm integration by converting one dry contact into a monitored Class B input and a Form C relay for immediate control actions
  • Reduces installation time with electrical-box mounting, accessible wiring terminals and support for 22–12 AWG conductors
  • Reliable SLC communication using a single loop address (SLC Class A/X/B) for seamless connection to Potter IPA series control panels
  • Visible status LED and DIP-switch addressing for fast troubleshooting and on-site configuration
  • Robust, code-ready design with US manufacture and a 5-year limited warranty for long-term system reliability
17 of 17 specifications
Technical specifications for Potter PAD100-OROI One Relay One Input Module
General Information
Sector Fire
Brand Name Potter Electric Signal, LLC
Manufacturer Potter Electric Signal, LLC
Product Name One Relay One Input Module
Product Type Relay Module
Product Model PAD100-OROI
Manufacturer Part Number 3992702
Technical Information
Application/Usage Control Panel, Fire Alarm Control Panel
Others
Model Number Replaces PAD100-OROI
Physical Characteristics
Color Red
Depth 1.1"
Width 4.2"
Form Factor Electrical Box Mount
Product Information
Length 4.2"
Mount Type Electrical Box Mount
Warranty
Limited Warranty 5-Year
Miscellaneous
Country of Origin US

No matching specifications

Try a different term, such as a connector type or resolution.

Plan your purchase

Is this right for your project?

Confirm the model, required accessories and delivery needs before ordering.

SKU:
3992702
Manufacturer part:
3992702
How do I confirm compatibility?

Check the specifications and manufacturer documents for your existing system. Send us your model numbers and project requirements if you need help selecting equipment or accessories.

Ask a product specialist
When will this item ship?

Availability is shown above. Special-order items and project quantities may need additional lead time. Contact us to confirm a delivery date before scheduling installation.

Shipping, freight and delivery details
What should I know about returns?

Returns require an approved RMA. Consult the linked return policy for deadlines and eligibility. For standard non-defective returns, eligible factory-sealed items carry a 15% restocking fee and customer-paid return shipping; open-box and used items are refused. Defective and DOA claims follow the policy's separate terms. Special orders and other exclusions are final sale.

Read return eligibility and exclusions

Potter PAD100-OROI One Relay One Input Module

3992702

Price & options