Cellar Saver CS-1829-C/O Closed or Open Sump Pump Failure Warning Sensor (Replacement for CS-2029W, CS-2029-C/C and CS-2029-O/C)

SKU: CS-1829-CO MPN: CS-1829-C/O Cellar Saver
Cellar Saver CS-1829-C/O Sump Pump Failure Warning Sensor
Product images for Cellar Saver CS-1829-C/O Closed or Open Sump Pump Failure Warning Sensor (Replacement for CS-2029W, CS-2029-C/C and CS-2029-O/C). 1 image(s) available. Click on image to view full size.

Key Features

  • Prevent costly basement flooding by providing early sump pump failure alerts that integrate with alarm and monitoring systems
  • Selectable open or closed circuit via a movable magnet for flexible wiring and easy compatibility with existing panels
  • Quick, drop-in installation with a standard 3/8" press-fit contact and a 3-foot lead—compatible replacement for CS-2029W, CS-2029-C/C and CS-2029-O/C
  • Reliable low-voltage signaling with a 250 mA rating and a durable, easy-to-clean housing for long service life
  • Recommended maintenance guidance (test 3×/year, contact replacement every 3 years) to keep your security and leak detection systems dependable

Quick Specifications

Product Model
CS-1829-C/O
Brand Name
Cellar Saver
Product Name
CS-1829-C/O Sump Pump Failure Warning Sensor
Product Type
Sump Pump Failure Warning Sensor
View Full Technical Specifications

Explore the details

Product information

CS-1829-C/O

Overview

Prevent basement flooding and protect equipment with the Cellar Saver CS-1829-C/O Sump Pump Failure Warning Sensor. This compact liquid leak and sump pump failure sensor provides selectable open or closed circuit operation—simply move the magnet from slot #2 to slot #1—so you can match wiring logic to alarm panels, building monitoring systems or security/surveillance integrations. The unit ships with a 3-foot lead and a 3/8" press-fit contact and is rated for up to 250 mA, delivering dependable low-voltage signaling for remote monitoring applications.

Designed as a direct replacement for CS-2029W, CS-2029-C/C and CS-2029-O/C models, the CS-1829-C/O reduces downtime and simplifies service for facility managers and integrators. Its robust housing resists corrosion and is easy to maintain (mild soap and brush cleaning recommended); manufacturers suggest testing three times per year and replacing contacts every three years to ensure continuous protection. Ideal for residential basements, commercial mechanical rooms and integrated security systems, this Cellar Saver sensor enhances leak detection and pump-failure monitoring. Order the CS-1829-C/O today or contact your distributor for installation assistance.

Features

  • Prevent costly basement flooding by providing early sump pump failure alerts that integrate with alarm and monitoring systems
  • Selectable open or closed circuit via a movable magnet for flexible wiring and easy compatibility with existing panels
  • Quick, drop-in installation with a standard 3/8" press-fit contact and a 3-foot lead—compatible replacement for CS-2029W, CS-2029-C/C and CS-2029-O/C
  • Reliable low-voltage signaling with a 250 mA rating and a durable, easy-to-clean housing for long service life
  • Recommended maintenance guidance (test 3×/year, contact replacement every 3 years) to keep your security and leak detection systems dependable
6 of 6 specifications
Technical specifications for Cellar Saver CS-1829-C/O Closed or Open Sump Pump Failure Warning Sensor (Replacement for CS-2029W, CS-2029-C/C and CS-2029-O/C)
General Information
Brand Name Cellar Saver
Manufacturer Cellar Saver, Inc
Product Name CS-1829-C/O Sump Pump Failure Warning Sensor
Product Type Sump Pump Failure Warning Sensor
Product Model CS-1829-C/O
Manufacturer Part Number CS-1829-C/O

No matching specifications

Try a different term, such as a connector type or resolution.

Plan your purchase

Is this right for your project?

Confirm the model, required accessories and delivery needs before ordering.

SKU:
CS-1829-CO
Manufacturer part:
CS-1829-C/O
How do I confirm compatibility?

Check the specifications and manufacturer documents for your existing system. Send us your model numbers and project requirements if you need help selecting equipment or accessories.

Ask a product specialist
When will this item ship?

Availability is shown above. Special-order items and project quantities may need additional lead time. Contact us to confirm a delivery date before scheduling installation.

Shipping, freight and delivery details
What should I know about returns?

Returns require an approved RMA. Consult the linked return policy for deadlines and eligibility. For standard non-defective returns, eligible factory-sealed items carry a 15% restocking fee and customer-paid return shipping; open-box and used items are refused. Defective and DOA claims follow the policy's separate terms. Special orders and other exclusions are final sale.

Read return eligibility and exclusions

Cellar Saver CS-1829-C/O Closed or Open Sump Pump Failure Warning Sensor (Replacement for CS-2029W, CS-2029-C/C and CS-2029-O/C)

CS-1829-C/O

Price & options