Fire-Lite MRP-2001E Six-Zone 24V Deluge-Preaction Control Panel for Single and Dual Hazard Deluge and Preaction Applications, 240V AC
Key Features
- Streamlines water-based suppression control for deluge and preaction systems, reducing installation complexity and ensuring fast, reliable activation when seconds count.
- Six supervised zones and programmable NACs provide flexible notification and releasing options, simplifying integration with building security and monitoring systems.
- 240VAC-capable MRP-2001E with supervised 24V outputs and 27.6V battery support ensures continuous operation and meets demanding facility uptime requirements.
- Compatible with System Sensor i3 detectors and conventional initiators for easy integration with existing fire detection, surveillance and alarm infrastructures.
- Built-in diagnostic displays, event history and Form-C relays improve serviceability and remote monitoring, reducing maintenance time and lifecycle cost.
Quick Specifications
- Brand Name
- Fire-Lite Alarms by Honeywell
- Manufacturer
- Honeywell International, Inc
- Product Name
- MRP-2001E Fire Alarm Control Panel
- Product Type
- Fire Alarm Control Panel
Product Information Tabs
Overview
For commercial, industrial and institutional facilities that require precise water-based releasing, the Fire-Lite Alarms by Honeywell MRP-2001E fire alarm control panel delivers dependable deluge and preaction protection with the flexibility integrators need. This six-zone fire alarm control panel is engineered to supervise wiring, AC power and battery health while providing programmable NACs, three Form-C relays and both resettable and non-resettable 24V outputs—helping ensure the right notification and releasing logic for dual-hazard scenarios. The MRP-2001E accepts System Sensor i3 and standard conventional detectors and supports 240VAC input for sites with higher-voltage feed requirements. Built-in diagnostics, an 80-character backlit LCD and a 256-event history log simplify commissioning, maintenance and remote monitoring, improving uptime and lowering lifecycle costs. UL 864 listing and NFPA-compatible features make this panel a compliant choice for sprinkler and suppression projects. Ideal for integrations with security, surveillance and facility monitoring systems, the MRP-2001E provides the reliable control and programmability required for mission-critical environments. Contact us to configure this panel for your deluge or preaction application.
Features
- Streamlines water-based suppression control for deluge and preaction systems, reducing installation complexity and ensuring fast, reliable activation when seconds count.
- Six supervised zones and programmable NACs provide flexible notification and releasing options, simplifying integration with building security and monitoring systems.
- 240VAC-capable MRP-2001E with supervised 24V outputs and 27.6V battery support ensures continuous operation and meets demanding facility uptime requirements.
- Compatible with System Sensor i3 detectors and conventional initiators for easy integration with existing fire detection, surveillance and alarm infrastructures.
- Built-in diagnostic displays, event history and Form-C relays improve serviceability and remote monitoring, reducing maintenance time and lifecycle cost.
| General Information | |
|---|---|
| Brand Name | Fire-Lite Alarms by Honeywell |
| Manufacturer | Honeywell International, Inc |
| Product Name | MRP-2001E Fire Alarm Control Panel |
| Product Type | Fire Alarm Control Panel |
| Product Model | MRP-2001E |
| Manufacturer Part Number | MRP-2001E |
| Technical Information | |
| Connectivity Technology | Wired |
| Number of Standard Zones | 6 |
| Battery Information | |
| Battery Voltage | 27.6 V DC |
| Battery Chemistry | Sealed Lead Acid (SLA) |
| Physical Characteristics | |
| Depth | 0.7" |
| Width | 16.8" |
| Height | 19.3" |
| Power Description | |
| Input Voltage | 230V AC |
| Miscellaneous | |
| Compatibility | 24 volt DC operation., 7.0 amps total 24 VDC output current., 80-character LCD display (backlit)., Adjustable waterflow discharge timer and two soak timers., Amseco, ANN-80 Remote LCD Annunciator, ANN-BUS for connection to optional devices (up to 8 total of any of the following):, ANN-I/O LED Driver, ANN-LED Annunciator Module, ANN-RLY Relay Module, ANN-S/PG Printer Module, Auto-Silence, Built-in Programmer., Cross-zone (double-interlock) capability., Designed for sprinkler standards NFPA 13, 15 and 16., Disable/Enable control per input zone and output zone., Dual hazard operation., Extensive transient protection., Faraday, FM Approved., Four programmable Style Y (Class B) output circuits - (special application power)., Gentex, History log with 256 event storage., Listed to UL Standard 864, 9th edition., Low AC voltage sense., NACs programmable for:, Outputs Programmable for:, Piezo sounder for alarm, trouble and supervisory., Real-time clock/calendar with daylight savings time control., Release Stage Sounder, Releasing circuits or NACS, Resettable and non-resettable output power., Selective Silence (horn-strobe mute), Silence Inhibit, Silenceable or Non-silenceable, Six programmable Style B (Class B) IDCs (Initiating Device Circuit)., Strobe Synchronization, Strobe Synchronization:, System Sensor, System Sensor i3 series detectors compatible., Temporal or Steady Signal, Three programmable Form-C relays., Wheelock |
| Country of Origin | US |