Potter PAD100-TRTI Relay Input Module

ADDR TWO RELAY /TWO INPUT
Product images for Potter PAD100-TRTI Relay Input Module. 2 image(s) available. Click on image to view full size.

Key Features

  • Simplifies installation and panel programming by using a single SLC loop address to monitor two inputs and two relays
  • Reduces field wiring and labor by supporting two Class B circuits or one Class A circuit for sprinkler and tamper monitoring
  • Provides two Form C relay contacts for reliable integration with building control, notification, and security systems
  • Surface-mount gang-box design and 22–12 AWG terminals deliver flexible mounting and easy access to wiring on site
  • Visual LED status indicator and UUKL listing ensure clear on-site diagnostics and compliance for smoke control applications
  • Backed by a 5-year warranty for long-term reliability in commercial fire and security environments

Quick Specifications

Product Model
PAD100-TRTI
Brand Name
Potter Electric Signal, LLC
Product Name
Two Relay Two Input Module
Product Type
Two-relay/Two-input Module
View Full Technical Specifications

Frequently Bought Together

This Item
Potter PAD100-TRTI Relay Input Module

Potter PAD100-TRTI Relay Input Module

$275.26

Frequently Bought Together (7 items)

8 items selected

Total: $983.69

Explore the details

Product information

PAD100-TRTI

Overview

Designed to simplify fire and security system integrations, the Potter PAD100-TRTI relay input module delivers dependable monitoring and control for sprinkler waterflow, valve tamper switches and conventional pull stations. This Potter Electric Signal, LLC two-relay/two-input module uses a single SLC loop address while monitoring two Class B circuits (or one Class A), reducing panel addresses and streamlining programming. Two Form C relay contacts provide dry-contact outputs for alarm management, suppression systems, or building automation interfaces, while an on-board LED gives fast visual confirmation of device polling and alarm activity.

Engineered for installers, the PAD100-TRTI mounts in a standard 4" square or double gang box and accepts 22–12 AWG wiring for quick field termination. Compatibility with Potter IPA and AFC/ARC addressable panels, UUKL listing for smoke control, and a 5-year warranty make it a practical choice for commercial fire alarm, security and monitoring projects. For reliable, compact relay input performance in your next surveillance or fire protection deployment, specify the PAD100-TRTI or contact sales to order.

Features

  • Simplifies installation and panel programming by using a single SLC loop address to monitor two inputs and two relays
  • Reduces field wiring and labor by supporting two Class B circuits or one Class A circuit for sprinkler and tamper monitoring
  • Provides two Form C relay contacts for reliable integration with building control, notification, and security systems
  • Surface-mount gang-box design and 22–12 AWG terminals deliver flexible mounting and easy access to wiring on site
  • Visual LED status indicator and UUKL listing ensure clear on-site diagnostics and compliance for smoke control applications
  • Backed by a 5-year warranty for long-term reliability in commercial fire and security environments
18 of 18 specifications
Technical specifications for Potter PAD100-TRTI Relay Input Module
General Information
Brand Name Potter Electric Signal, LLC
Manufacturer Potter Electric Signal, LLC
Product Name Two Relay Two Input Module
Product Type Two-relay/Two-input Module
Product Model PAD100-TRTI
Application/Usage Conventional Pull Station, Fire Alarm Control Panel, Heat Detector, Valve Tamper Switch, Waterflow Switch
Manufacturer Part Number PAD 100-TRTI
Environmental Conditions
Relative Humidity 0.93
Maximum Operating Temperature 120°F
Minimum Operating Temperature 32°F
Physical Characteristics
Color Red
Depth 1.10"
Width 4.20"
Form Factor Gang Box Mount
Product Information
Mount Type Gang Box Mount
Warranty
Limited Warranty 5-Year
Miscellaneous
Features LED Indicator
Compatibility Potter IPA and AFC/ARC series addressable fire alarm control panels

No matching specifications

Try a different term, such as a connector type or resolution.

Plan your purchase

Is this right for your project?

Confirm the model, required accessories and delivery needs before ordering.

SKU:
PAD100-TRTI
Manufacturer part:
PAD100-TRTI
How do I confirm compatibility?

Check the specifications and manufacturer documents for your existing system. Send us your model numbers and project requirements if you need help selecting equipment or accessories.

Ask a product specialist
When will this item ship?

Availability is shown above. Special-order items and project quantities may need additional lead time. Contact us to confirm a delivery date before scheduling installation.

Shipping, freight and delivery details
What should I know about returns?

Returns require an approved RMA. Consult the linked return policy for deadlines and eligibility. For standard non-defective returns, eligible factory-sealed items carry a 15% restocking fee and customer-paid return shipping; open-box and used items are refused. Defective and DOA claims follow the policy's separate terms. Special orders and other exclusions are final sale.

Read return eligibility and exclusions

Potter PAD100-TRTI Relay Input Module

PAD100-TRTI

Price & options