Categories
Loading categories…

Potter PS100-2 Excess Pressure Pump Supervisory Switch with 2-SPDT Contacts

Special Order: typically 2–6 weeks

Ships directly from the manufacturer. This is an estimated lead time, not a guaranteed delivery date.

Availability can change and lead times may be longer. If your project has a deadline, check with us before ordering.

A member of our team will check with the manufacturer and personally reply by email.

Potter Excess Pressure Pump Supervisory Switch
Product images for Potter PS100-2 Excess Pressure Pump Supervisory Switch with 2-SPDT Contacts. 1 image(s) available. Click on image to view full size.

Key Features

  • Reliable pump supervision with factory-set activation at 90 PSI (6.2 BAR) to detect excess-pressure drops and protect sprinkler systems
  • Dual SPDT contacts provide independent supervisory and alarm circuits for flexible system integration
  • Tool-free independent switch adjustment simplifies commissioning and maintenance to reduce downtime
  • Rugged, non-corrosive pressure connection and non-conductive enclosure ensure long life in indoor or outdoor pump rooms
  • Separate isolated wiring chambers with two 1/2" conduit entries streamline installation and maintain clean signal integrity for monitoring

Quick Specifications

Product Model
PS100-2
Brand Name
Potter Electric Signal, LLC
Product Name
Excess Pressure Pump Supervisory Switch
Product Type
Pressure Actuated Switch
View Full Technical Specifications

Explore the details

Product information

PS100-2

Overview

Ensure dependable pump supervision and sprinkler system monitoring with the Potter Electric Signal, LLC PS100-2 Excess Pressure Pump Supervisory Switch. This pressure actuated switch is engineered for automatic fire sprinkler and pump systems to detect drops from excess-pressure conditions, giving you early supervisory notification to prevent service interruptions. The PS100-2 includes two SPDT contacts for independent alarm and supervisory outputs and is factory-set to operate on a pressure drop at 90 PSI (6.2 BAR), delivering reliable, repeatable performance for critical life-safety applications. Installers benefit from tool-free independent switch adjustment, two 1/2" conduit/cable entrances, and isolated wiring chambers that simplify wiring and reduce labor time. Built with a non-corrosive pressure connection and a non-conductive enclosure, the PS100-2 stands up to pump room environments whether indoor or outdoor. Ideal for integration with security, fire monitoring, and building management systems, the PS100-2 enhances surveillance and system reliability without complicating installation. Add the Potter PS100-2 to your next specification to improve pump circuit supervision and overall sprinkler monitoring — order now to secure system uptime.

Features

  • Reliable pump supervision with factory-set activation at 90 PSI (6.2 BAR) to detect excess-pressure drops and protect sprinkler systems
  • Dual SPDT contacts provide independent supervisory and alarm circuits for flexible system integration
  • Tool-free independent switch adjustment simplifies commissioning and maintenance to reduce downtime
  • Rugged, non-corrosive pressure connection and non-conductive enclosure ensure long life in indoor or outdoor pump rooms
  • Separate isolated wiring chambers with two 1/2" conduit entries streamline installation and maintain clean signal integrity for monitoring
11 of 11 specifications
Technical specifications for Potter PS100-2 Excess Pressure Pump Supervisory Switch with 2-SPDT Contacts
General Information
Brand Name Potter Electric Signal, LLC
Manufacturer Potter Electric Signal, LLC
Product Name Excess Pressure Pump Supervisory Switch
Product Type Pressure Actuated Switch
Product Model PS100-2
Application/Usage Indoor, Outdoor
Country of Origin US
Manufacturer Part Number PS100-2
Physical Characteristics
Depth 3.20"
Width 3.80"
Height 4.20"

No matching specifications

Try a different term, such as a connector type or resolution.

Plan your purchase

Is this right for your project?

Confirm the model, required accessories and delivery needs before ordering.

SKU:
PS100-2
Manufacturer part:
PS100-2
How do I confirm compatibility?

Check the specifications and manufacturer documents for your existing system. Send us your model numbers and project requirements if you need help selecting equipment or accessories.

Ask a product specialist
When will this item ship?

Availability is shown above. Special-order items and project quantities may need additional lead time. Contact us to confirm a delivery date before scheduling installation.

Shipping, freight and delivery details
What should I know about returns?

Returns require an approved RMA. Consult the linked return policy for deadlines and eligibility. For standard non-defective returns, eligible factory-sealed items carry a 15% restocking fee and customer-paid return shipping; open-box and used items are refused. Defective and DOA claims follow the policy's separate terms. Special orders and other exclusions are final sale.

Read return eligibility and exclusions

Potter PS100-2 Excess Pressure Pump Supervisory Switch with 2-SPDT Contacts

PS100-2

Price & options