Potter PAD100-DIM Dual Input Module
Key Features
- Uses a single SLC loop address to monitor two Class B circuits or one Class A circuit, reducing panel address usage and simplifying wiring
- Dual inputs let you monitor sprinkler waterflow and valve tamper switches in the same location, saving installation time and materials
- Mounts in a standard 4" square or double-gang box with accessible terminals for faster installation and maintenance
- Red LED status indicator provides clear visual feedback during polling and active alarms for quicker troubleshooting
- Compatible with SLC Class A, Class X and Class B control panels and accepts 22–12 AWG to minimize inventory complexity
- Backed by a 5-year limited warranty for dependable long-term performance in fire and security systems
Quick Specifications
- Product Model
- PAD100-DIM
- Brand Name
- Potter Electric Signal, LLC
- Product Name
- Dual Input Module
- Product Type
- Addressable Input Module
Frequently Bought Together
Potter PAD100-DIM Dual Input Module
$113.16
$117.54
8 items selected
Total: $936.41
Explore the details
Product information
PAD100-DIM
Overview
Streamline fire and security monitoring with the Potter Electric Signal PAD100-DIM dual input module. This addressable input module consolidates two supervised inputs into a single SLC loop address, reducing control panel address consumption and simplifying wiring for sprinkler waterflow, valve tamper, and other supervised contacts. The PAD100-DIM mounts in a standard 4-inch square or double-gang box and accepts 22–12 AWG wiring for fast, flexible installation. A red status LED offers immediate visual confirmation—slow flashing during normal polling and rapid flashing on active inputs—speeding diagnostics and service.
Designed for use with SLC Class A, Class X and Class B control panels and powered by 24 VDC, the PAD100-DIM delivers reliable monitoring performance for commercial security and fire alarm applications. Its compact red housing and accessible wiring terminals reduce installation time and maintenance complexity, making it an efficient choice for contractors and facility managers. Ideal for integrating sprinkler waterflow and tamper supervision into addressable systems, the PAD100-DIM helps you maintain code-compliant, dependable protection. Contact your distributor or add it to your next control panel spec to improve monitoring efficiency.
Features
- Uses a single SLC loop address to monitor two Class B circuits or one Class A circuit, reducing panel address usage and simplifying wiring
- Dual inputs let you monitor sprinkler waterflow and valve tamper switches in the same location, saving installation time and materials
- Mounts in a standard 4" square or double-gang box with accessible terminals for faster installation and maintenance
- Red LED status indicator provides clear visual feedback during polling and active alarms for quicker troubleshooting
- Compatible with SLC Class A, Class X and Class B control panels and accepts 22–12 AWG to minimize inventory complexity
- Backed by a 5-year limited warranty for dependable long-term performance in fire and security systems
| General Information | |
|---|---|
| Brand Name | Potter Electric Signal, LLC |
| Manufacturer | Potter Electric Signal, LLC |
| Product Name | Dual Input Module |
| Product Type | Addressable Input Module |
| Product Model | PAD100-DIM |
| Country of Origin | US |
| Manufacturer Part Number | PAD 100-DIM |
| Technical Information | |
| Device Supported | Control Panel |
| Environmental Conditions | |
| Maximum Operating Temperature | 120°F |
| Minimum Operating Temperature | 32°F |
| Physical Characteristics | |
| Color | Red |
| Depth | 1.10" |
| Width | 4.20" |
| Height | 4.20" |
| Power Description | |
| Input Voltage | 24V DC |
| Warranty | |
| Limited Warranty | 5-Year |
No matching specifications
Try a different term, such as a connector type or resolution.
Plan your purchase
Is this right for your project?
Confirm the model, required accessories and delivery needs before ordering.
- SKU:
- PAD100-DIM
- Manufacturer part:
- PAD100-DIM
How do I confirm compatibility?
Check the specifications and manufacturer documents for your existing system. Send us your model numbers and project requirements if you need help selecting equipment or accessories.
Ask a product specialistWhen will this item ship?
Availability is shown above. Special-order items and project quantities may need additional lead time. Contact us to confirm a delivery date before scheduling installation.
Shipping, freight and delivery detailsWhat should I know about returns?
Returns require an approved RMA. Consult the linked return policy for deadlines and eligibility. For standard non-defective returns, eligible factory-sealed items carry a 15% restocking fee and customer-paid return shipping; open-box and used items are refused. Defective and DOA claims follow the policy's separate terms. Special orders and other exclusions are final sale.
Read return eligibility and exclusionsPotter PAD100-DIM Dual Input Module
PAD100-DIM